how to calculate heat rate of power plant xls

Heat rate of power plant: divided by 1000 X Electrictry delivered in month (400 Mwh x peak days) divided by Size of fuel contract million Btus Calculate Hedge Ratio: The heat rate of the generating plant is the number of Btus needed to generate one kilowatt hour of ...

Read More

01-12-2016· To calculate pipe heat loss, the basic heat loss equation (Q) is rewritten as: where. 2 π is part of the formula for calculating the area of a cylinder. 40.944 is 12" of pipe multiplied by the 3.412 conversion factor. D o is the outer insulation diameter, D i is the inner insulation diameter.

Read More

Heat Rate: The heat rate as expressed in MMBtu/MWh. A more common reference for heat rates is typically Btu/kWh: simply multiply the given heat rate by 1,000 to convert from MMBtu/MWh to Btu/kWh. NOTE: The information in the following table can be copied to a spreadsheet program such as MS Excel by highlighting the desired records and then copying and pasting them into a spreadsheet.

Read More

Ł Part Two deals with complex plant where there are many channels of heat flow. In this case, ... calculated and added to the heat in steam. 1.6.3 Boiler Efficiency by Direct Method: ... It is suggested that the exit duct of the boiler be probed and traversed to find the location of the 1. Energy Performance Assessment of Boilers. 1.

Read More

02-11-2011· Calculation procedure: 1) Enter the required data on input page just replace the existing values: 2) Go to detailed calculation sheet there you get explanation of entire calculations: 3) Heat balance report can be printed on Output page

Read More

NOTES: Gas fuel based on 9% CO2, #2 Oil fuel based on 13% CO2 emissions. 80% Thermal Efficient Boiler 85+% Efficient Combustion Excess Air Volume=15% Fuel Gas=1/Oil=0 1 Enter 1 or 0 Flue Gas Temperature 325 Boiler Horsepower 1200 Exhaust Volume 126,949.14 Actual Cubic Feet/Min. At Stack Temperature Emissions Make-Up Percent of Flue Gases Excess ...

Read More

– This is the rate to be charged on the capital cost of the plant in order to convert capital costs (ie investment) into operating costs (or annual costs). This rate can be estimated in a number of ways. This rate generally includes most of our ignorance about the future (ie interest rates, ROE, inflation, taxes, etc.) zDiscounted Cash Flow ...

Read More

21-10-2011· TURBINE CYCLEPERFORMANCE CALCULATION 1.Turbine cycle heat rate calculation.(210 MW –KWU Turbine) 2.HP turbine (HP cylinder ) efficiencycalculation .(210 MW –KWU Turbine) 3. WHAT IS HEAT RATE OF TURBINECYCLE Heat rate is the heat input requiredper unit of power generated, forspecific fuel being fired and specificsite conditions. 4.

Read More

15-09-2006· Typically, when plant guarantees are tied to corrected output and heat rate, the two most important instrument readings are measured power and fuel flow. If either is wrong, the test results will ...

Read More

How does the Heat Sink Calculator Work? This tool is designed to calculate junction temperature of an electronic device (typically power devices) given four parameters: the maximum ambient temperature, the device's junction-to-package thermal resistance, the thermal resistance of the heat sink, and the power …

Read More

17-08-2020· Heat rate is one measure of the efficiency of electrical generators/power plants that convert a fuel into heat and into electricity. The heat rate is the amount of energy used by an electrical generator/power plant to generate one kilowatthour (kWh) of electricity.

Read More

16-11-2010· Calculator Use. Convert among units of power and heat flow. (IT) = International Table (th) = Thermochemical; How to Convert Units of Power and Heat Flow. Conversions are performed by using a conversion factor. By knowing the conversion factor, converting between units can become a simple multiplication problem: S * C = E

Read More

4 Heat Rate is a measure of generating station thermal efficiency commonly stated as Btu per kilowatthour. 5 U.S. Energy Information Administration, Annual Energy Outlook 2016, Table 20, GDP chain‐type price index

Read More

06-10-2010· Download the Excel spreadsheet templates in this article to make preliminary heat exchanger design calculations. These templates use S.I. units and U.S. units. Calculate the required heat transfer area based on values needed. They will also calculate the number of tubes needed for a shell and tube heat exchanger and to calculate the pipe length needed for a double pipe heat …

Read More

12-09-2018· Waste heat recovery systems produce power by consuming the heat energy lost to the surroundings from thermal processes, with no additional fuel input. For marine vessels, about 50% of the total fuel energy supplied to the diesel power plants is lost to the surroundings [ 9 ].

Read More

A more common reference for heat rates is typically Btu/kWh: simply multiply the given heat rate by 1,000 to convert from MMBtu/MWh to Btu/kWh. NOTE: The information in the following table can be copied to a spreadsheet program such as MS Excel by highlighting the desired records and then copying and pasting them into a spreadsheet.

Read More

The Combined Heat and Power (CHP) Emissions Calculator (CEC) is a Microsoft Excel-based tool that calculates and compares the estimated air pollutant emissions (CO2e, SO2 and NOX) of a CHP system and comparable separate heat and power (SHP) (i.e., grid power and a boiler system).

Read More

14-12-2012· Thermal power plant heat rate calculator.xls trend: Nuclear Power … Thermal power plant heat rate calculator.xls in Title/Summary. Nuclear Power . … where as isentropic efficiency and power output of steam turbine.

Read More

power plants. These factors — including construction costs, fuel expense, environmental regulations, a nd financing costs — can all be affected by government energy and economic policies. Government decisions to in fluence, or not influence, these factors can largely determine the kind of power plants that are built in the future.

Read More

24-10-2008· How do you calculate the efficiency of a power plant when you know its heat rate? Efficiency = (860.4*100)/(Heat rate in kCal/kWh)

Read More

22-09-2018· Hydraulic power Ph = Flow rate X Total developed head X Density X Gravitational constant. Pump Efficiency is the ratio of pump input and output power. i.e Efficiency of the pump is the ratio water horse power to break horse power. Pump input power calculation formula or pump shaft power calculation formula. Pump Input Power = P. Formula – 1

Read More

Heat Rate (Energy Efficiency) Overall thermal performance or energy efficiency for a power plant for a period can be defined as. φhr = H / E (1) where. φhr = heat rate (Btu/kWh, kJ/kWh) H = heat supplied to the power plant for a period (Btu, kJ) E = energy output from the power plant in the period (kWh)

Read More

12-02-2021· 32-In a coal based Thermal power plant, a 10" steam line is left uninsulated around 2 meters of its length. Because of this there is a loss of heat around 17500 kcal/hr .Calculate the extra fuel consumption in a day to compensate this loss. Consider coal GCV & boiler efficiency 4500 kcal/kg & 90% respectively. We have,

Read More

09-03-2017· The Plant Energy Profiler Excel, or PEPEx, is an excel based software tool provided by the U.S. Department of Energy to help industrial plant managers in the United States identify how energy is being purchased and consumed at their plant and identify potential energy and cost savings.

Read More